Specification

Specification for Exterior Co-extruded WPC Wall Panel
Section 169 × 24 mm, exterior co-extruded, supplied made to order
Skin UV-stabilised cap, formulated for sunlight rather than interior wear
Assembly Drained and ventilated rainscreen over battens — the cavity is not optional
Movement Allow at every run end and at long joints, and fix so the panel can slide
Exposure Confirm coastal or sheltered exposure before specifying; salt is a harder case
Standard SGS tested. CE documentation supplied with EU-bound orders.
Maintenance Wipe clean. No paint or oil finish required.

What this product does

  1. 1
    UV-stabilised cap

    The skin is formulated for sunlight rather than interior wear

  2. 2
    Rainscreen assembly

    Drained and ventilated cavity over battens, and the cavity is not optional

  3. 3
    Thermal movement allowed

    Run ends and long joints let the panel slide rather than buckle

  4. 4
    Moisture-proof core

    Backs the cap so rain that reaches the core does not swell it

Description

An exterior-grade wood-plastic cladding panel, 169 × 24 mm, with a UV-stabilised cap co-extruded over a moisture-proof core. It sits in the same section family as the interior panels, at 154 × 17 mm and 168 × 22 mm, and the difference is entirely in the skin: the cap is formulated for sunlight and weather rather than for interior wear.

It goes on facades, sheltered exteriors, soffits and balcony walls, and it is installed as a drained and ventilated rainscreen: battens set out to the panel joint, a cavity behind, and the panel fixed so it can slide. The cavity is not optional. It is what lets the wall dry after driven rain, and a facade without it will show damp at the substrate long before it shows anything on the panel face. Because the composite moves with temperature, every run needs an allowance at its ends and at long joints, and pinning the panel rather than letting it slide is the most common installation mistake.

For an open coastal elevation, tell us the location and the height above ground before specifying, because salt and driven rain are a harder exposure than a sheltered inland facade and the fixing strategy has to match.

Where it is used

Villa facades and gable ends

The elevation that takes the sun all afternoon, where an interior skin would chalk

Balcony and terrace soffits

Sheltered but driven at by rain, and small enough to detail a cavity properly

Canopy and entrance surrounds

A face that gets touched, rained on and inspected at close range

Coastal low-rise elevations

Salt is the harder case, and the fixing strategy carries as much as the panel

See all application guides

Frequently asked

What is the minimum order?

1 × 20ft container, mixed across products where the mix suits the project. A sample box can be arranged before the first container.

Can I see a sample before ordering?

Yes. Send the product and the size you are specifying, and we will confirm the sample and the lead time for it.

What makes the exterior grade different?

The skin. It is a UV-stabilised cap co-extruded over the core, so the pigment sits in a layer built to take sunlight. The interior panel has a skin built for wear instead, and putting it outside is the substitution that fails.

Does it need expansion gaps?

Yes. The panel moves with temperature, so every run needs an allowance at its ends and at long joints, and the fixing has to let the panel slide rather than pin it. A facade that is fixed tight will buckle at the joint rather than at the end.

Can it go on a coastal elevation?

Ask before you specify. Salt and driven rain are a harder exposure than a sheltered inland facade, and the fixing and substrate matter as much as the panel. Tell us the location and the height above ground when you enquire.

What goes behind it?

A drained and ventilated cavity over a suitable substrate, with battens set out to the panel joint. The cavity is what lets the wall dry, so it is not optional on an exterior.

Trade terms

MOQ
1 × 20ft container
Lead time
15-25 days
Payment terms
T/T 30% deposit, balance before shipment

Final packing, freight and loading plan are confirmed in writing on the order quotation.

Related products

All in this category

Technical reading

  • 50+ Countries shipped to
  • 2003 Established
  • 20,000 m² factory area
  • 20 Production lines
  • 80 Employees
  • 15 Product lines
  • 5M m² annual capacity

Ask about this product

Tell us the size, the quantity and the destination port. We will come back with price, lead time and the packing plan.

  • Reply within one business day
  • No obligation, no account needed
  • Drawings and specs stay confidential

Get My Quote

The product name and SKU are filled in for you.

Ask on WhatsApp

We reply within one business day. Your drawings and specs stay confidential.

Chat with our export team